Site Announcement

Sign up today and receive company updates straight to your inbox

A Mile of Margin: Building the Safety Case for the Gravity™ Reactor (Vol. 1)

« View all Stories

Gravity Reactor Simulation and Analysis

By: Aleem Boatright, PE, Director of Nuclear Analysis

The Deep Fission Engineering team has completed its first coupled simulation of the most severe reactivity transient currently postulated for the Gravity Reactor. In plain terms, a reactivity transient is any event that pushes the reactor’s power up or down, and a coupled simulation is a computer model that tracks the reactor’s nuclear physics and its cooling water together, so each can respond to the other as the event unfolds.

The event we modeled is a boron dilution, in which all of the boron in the reactor core is deliberately washed out. With no shutdown system and no operator action assumed to help, the simulated reactor settled at a new, seemingly stable power level.

How the Gravity Reactor controls its power

Most reactors use control rods, movable rods that absorb neutrons (the tiny particles that keep a nuclear chain reaction going), to slow or stop the reaction. The Gravity Reactor has no control rods. Instead, its power is controlled by boron, a naturally occurring element that absorbs neutrons, dissolved in the water that cools the reactor. More boron in the water means less power; less boron means more power.

The most direct way to challenge a reactor like this is to remove that boron, for example by accidentally adding plain water with no boron in it, which raises the reactor’s power. That is the event we chose to analyze first.

How we set up the simulation

The simulation starts with the reactor running at full power with fresh fuel. Pure water is then pumped in through one of the main coolant pipes, at full flow and without stopping, until all of the boron in the core is gone. In this simulation, we assumed that:

  • the reactor’s boron injection shutdown system, which is designed to add boron back and shut the reactor down, does not operate;
  • no operator steps in to stop the dilution; and
  • no extra cooling is provided from the surface.

What we found

The results of our analysis: the event is slow, the fuel stays cool, and the surroundings barely notice.

The reason the reactor’s power levels off on its own is a basic property of its physics called negative reactivity feedback. We explain it in this week’s Nuclear Safety Question of the Week, below.

Why it matters

This is just one simulation, so why does this matter? A conventional pressurized water reactor (PWR), the most common type of nuclear power plant in the United States, relies on its reactor protection system to automatically drive control rods into the core and stop a rapid power increase before the fuel reaches its limits.

The Gravity Reactor is intended to achieve stability without that intervention. Instead, it relies on three things:

  • The physics of its fuel. As the fuel and water heat up, they naturally slow the chain reaction.
  • Natural circulation. Water moves through the reactor on its own, because heated water rises and cooler water sinks.
  • Low power density by design. Each part of the core is asked to produce relatively little heat, so the fuel is not pushed hard.

These simulations are designed to assess and demonstrate that natural, passive behavior.

What comes next

Model refinements are now under way to simulate additional scenarios and complications. The full suite of transients, meaning the complete set of events we plan to simulate, is tentatively scheduled for completion by the end of the year.

Simulations like this one answer the question “How bad could it be?” for the events we have already identified. Equally important is making sure that list of events is complete. From November 9 to 11, the Deep Fission Engineering team conducted a workshop to identify additional hazards that are unique to a reactor operating a mile underground.

This update is the first in a series. Over the coming weeks, we will describe where nuclear safety analysis came from, how our process works, what we’re currently finding, and how these factors all work together to help analyze the Gravity Reactor safety case, the full body of analysis and evidence used to evaluate whether a reactor can operate safely.

Callout_Mark_standalone_1x.png

Test your knowledge: What is negative reactivity feedback?

“Reactivity” describes whether a reactor’s chain reaction is growing, shrinking, or holding steady. In a pressurized water reactor (PWR) like the Gravity Reactor, the fuel and the water that slows neutrons both become less effective at sustaining the chain reaction as they heat up. In other words, the hotter the reactor gets, the more it naturally holds itself back.

Power therefore falls as temperature rises, without any device or action. This physical property cannot be switched off, and it is the reason that the boron dilution scenario described above levels off rather than running away.

General Disclaimer

The process and results described in this update come from a simulation of the Gravity Reactor design under specific conditions and in a controlled setting. These results are preliminary and may not be representative of the performance, efficiency, reliability, or safety of the Gravity Reactor in other conditions, at commercial scale, over longer periods of operation, or in real-world deployment.

Forward-Looking Statements

This article contains forward-looking statements within the meaning of the federal securities laws. Forward-looking statements include, but are not limited to, statements regarding Deep Fission’s business strategy, technology development plans, and the timing, feasibility, scalability, safety, and performance of Deep Fission’s technology. These statements include the anticipated safety profile of Deep Fission’s Gravity Reactor, future refinements and any further updates reflected in future articles of this series. These statements are based on current expectations and assumptions and are subject to risks and uncertainties that could cause actual results to differ materially from those expressed or implied.

Important factors that may cause actual results to differ materially include, among others, the actual operation of the Gravity Reactor in situ following deployment and the other risks described under “Risk Factors” and “Cautionary Note Regarding Forward-Looking Statements” in Deep Fission’s filings with the Securities and Exchange Commission.

Forward-looking statements speak only as of the date of this article. Deep Fission undertakes no obligation to update any forward-looking statements, except as required by law.


Company News